AETHER-180 Oil-Free Dental Air Compressor
AETHER-180 Oil-Free Dental Air Compressor:Dental Air Compressor, also known as the Oil‑Free Dental Compressor deployed in the Dental Clinic or hospital, supplies Compressed Air as the power source for the Dental Unit, driving both high‑speed turbine dental handpieces and low‑speed pneumatic handpieces during procedures such as tooth drilling. It features Low Noise and delivers Stable Pressure for consistent clinical performance.
Interview
Number of dental comprehensive treatment chairs equipped:
Suitable for use with 15 to 20 dental comprehensive treatment chairs.
Equipment Use:
This dental treatment device, intended for use in hospitals or dental clinics, serves as the power source for both the high-speed turbine dental handpiece and the low-speed pneumatic motor handpiece during procedures such as tooth drilling.
Equipment Use:
When dental treatment equipment (e.g., dental drilling devices) is in use for procedures such as tooth drilling, this unit serves as the power source for both the high-speed turbine dental handpiece and the low-speed pneumatic motor handpiece.
Operating Conditions :
Environmental Conditions :
Power Supply Conditions:
Technical Specifications :
Compressor Configuration List: :
Compressor Pump × 2;
Air Intake Filter × 8;
Metal High-Pressure Hose × 2;
Microcomputer Control System × 1;
QPS Filter × 1
Q: How many dental chairs can it support?
A: 15–20 dental comprehensive treatment chairs.
Q: What is the main purpose?
A: Power source for high-speed turbine and low-speed pneumatic dental handpieces during procedures such as tooth drilling.
Q: What are the power and environment requirements?
A: AC 380 V ±10%, 50 Hz, 4.8 kW. Ambient 5–40°C, humidity ≤ 70%, pressure 86–106 kPa, ventilation ≥ 0.20 m³/s. Noise ≤ 79 dB.
Q: What is the air supply performance?
A: Two oil-free V-shaped four-cylinder heads, motor ≥ 1400 rpm, 320 L/min per head at 0.6 MPa, total 640 L/min, with a 180 L air tank. Max pressure 1.0 MPa.
Q: How is it controlled and protected?
A: Microcomputer controller with independent start/stop per motor, time-sharing start, under-voltage protection, and overcurrent protection. Includes an automatic drain valve for timed drainage.
Q: What filtration and hygiene features does it have?
A: QPS comprehensive filter removes dust, water, and oil with up to 90% efficiency. The 180 L tank has a nano-antibacterial coating for rust, bacteria, and mold prevention.
| Category | Item | Content |
|---|---|---|
| Number of Dental Chairs Equipped | Suitable for use with | 15 to 20 dental comprehensive treatment chairs |
| Equipment Use | Application (1) | This dental treatment device, intended for use in hospitals or dental clinics, serves as the power source for both the high-speed turbine dental handpiece and the low-speed pneumatic motor handpiece during procedures such as tooth drilling. |
| Application (2) | When dental treatment equipment (e.g., dental drilling devices) is in use for procedures such as tooth drilling, this unit serves as the power source for both the high-speed turbine dental handpiece and the low-speed pneumatic motor handpiece. | |
| Environmental Conditions | Ambient Temperature | 5°C – 40°C |
| Relative Humidity | ≤ 70% | |
| Atmospheric Pressure | 86 – 106 kPa | |
| Ventilation Flow Rate | ≥ 0.20 m³/s | |
| Power Supply Conditions | Rated Voltage | AC 380 V ± 10% |
| Frequency | 50 Hz | |
| Rated Power | 4.8 kW | |
| Noise Level | ≤ 79 dB | |
| Air Tank Capacity | 180 L | |
| Technical Specifications | Compressor Type | Oil-free piston-type V-shaped four-cylinder air compressor |
| Motor Speed | ≥ 1400 rpm | |
| Nominal Flow Rate | 320 L/min (0.6 MPa) | |
| Maximum Pressure | 1.0 MPa | |
| Total Air Output Rate | 640 L/min (0.6 MPa) | |
| Parallel Operation | Two compressor heads are operated in parallel, equipped with an 180 L air storage tank | |
| Air Storage Tank Treatment | The air storage tank is treated for rust prevention with a nano-antibacterial coating to prevent bacterial and mold growth, ensuring a clean and hygienic air supply | |
| Motor Start / Stop | The two motors start and stop in time-sharing mode to reduce starting current; each motor can be started and stopped independently | |
| Controller Protection | Microcomputer controller with under-voltage protection and overcurrent protection | |
| Automatic Drain Valve | Equipped with an automatic drain valve for timed drainage to prevent water accumulation in the tank and extend the service life of both high- and low-speed handpieces | |
| Technical Specifications | Filter | Equipped with a QPS comprehensive filter, which effectively removes dust, water, and oil from compressed air, achieving a filtration efficiency of up to 90% |
| External Dimensions | (Length × Width × Height) ≤ 150 × 63 × 90 cm | |
| Weight | ≤ 175 kg |
| Item | Quantity |
|---|---|
| Compressor Pump | ×2 |
| Air Intake Filter | ×8 |
| Metal High-Pressure Hose | ×2 |
| Microcomputer Control System | ×1 |
| QPS Filter | ×1 |