AEOLUS-pro -15 Dental Water Ring Suction System
AEOLUS-pro -15 Dental Water Ring Suction System:Dental Negative Pressure Suction Machine is specially designed for professional treatment scenarios in dental clinics and hospitals. Serving as an essential supporting device for dental treatment units during various dental procedures such as tooth drilling, this high-performance oral suction machine effectively aspirates saliva, blood, oral debris, and aerosol mist generated by high-speed turbine handpieces. Integrated with three-in-one functions
Interview
Capacity:
Suitable for 10–15 dental comprehensive treatment units.
Equipment Purpose:
Used as a suction power source for aspirating saliva, blood, small particles, or other fluids during dental procedures (e.g., tooth drilling) in hospitals or dental clinics; also features a water vapor separation and automatic discharge function.
Operating Conditions:
Environmental Conditions :
Power Supply Conditions :
Technical Specifications
Configuration List:
Vacuum Pump – 1;
Separator – 1;
Vacuum Tube – 1;
Drain Pipe – 1;
Vacuum Tube – 1
| Dental Water-Ring Suction Pump — Technical Specification | |||
| Section | Item / Parameter | Specification | Remarks |
| 1. General / Capacity | |||
| 1. General / Capacity | Suitable Capacity | 10–15 dental comprehensive treatment units | |
| 2. Equipment Purpose | |||
| 2. Equipment Purpose | Main Function | Used as a suction power source for aspirating saliva, blood, small particles, or other fluids during dental procedures (e.g. tooth drilling) in hospitals or dental clinics. | |
| 2. Equipment Purpose | Additional Function | Features a water vapor separation and automatic discharge function. | |
| 3. Operating Conditions - Environmental | |||
| 3. Operating Conditions - Environmental | Ambient Temperature | 5 °C – 40 °C | |
| 3. Operating Conditions - Environmental | Relative Humidity | ≤ 70 % | |
| 3. Operating Conditions - Environmental | Atmospheric Pressure | 86 – 106 kPa | |
| 3. Operating Conditions - Environmental | Ventilation Flow Rate | ≥ 0.30 m³/s | |
| 3. Operating Conditions - Power Supply | |||
| 3. Operating Conditions - Power Supply | Rated Voltage | AC 220 V ±10 % | |
| 3. Operating Conditions - Power Supply | Frequency | 50 Hz | |
| 3. Operating Conditions - Power Supply | Rated Power | 3.6 kW | |
| 4. Technical Specifications | |||
| 4. Technical Specifications | Instant Suction & Max Vacuum | Water-ring suction pump instantly generates a high suction flow rate compliant with dental application standards without waiting time; maximum vacuum: –50 kPa. | |
| 4. Technical Specifications | Pump Configuration | Two high-flow vacuum pumps operate in parallel; can be started simultaneously in time-sharing mode or operate independently as backup units, providing maximum reliability for outpatient dental care. | |
| 4. Technical Specifications | Wet Suction System | Integrated modular wet suction system with an external independent water–gas separator, enabling continuous active discharge of wastewater. | |
| 4. Technical Specifications | Corrosion Resistance | Stainless steel pump body, stainless steel impeller and stainless steel base, which effectively extend the pump's service life. | |
| 4. Technical Specifications | Control System | Intelligent microcomputer control system allows independent control of the operating status of each vacuum pump, incorporates multiple circuit protection functions and includes an automatic delayed shutdown feature. | |
| 4. Technical Specifications | Negative Pressure Balancing | External mechanical negative pressure balancing valve ensures negative pressure stays within the optimal range of –11 to –15 kPa, preventing damage to the patient's oral mucosa caused by excessive negative pressure. | |
| 4. Technical Specifications | Emergency Startup | One-touch emergency startup: in the event of a microcomputer system failure, the device can be activated via a single button press to enter emergency mode, allowing it to continue operating while awaiting repair or rescue services. | |
| 4. Technical Specifications | Water Supply | The solenoid valve and check valve work in conjunction to ensure a stable supply of tap water; water intake filtration treatment protects the vacuum pump from damage during normal operation. | |
| 4. Technical Specifications | Water Saving | Equipped with a proprietary water circulation system that can reduce tap water consumption by up to 40%. | |
| 4. Technical Specifications | Cooling | The mechanical negative pressure balancing valve provides sufficient fresh air for internal cooling and heat dissipation of the suction pump. | |
| 4. Technical Specifications | Water Supply Pressure | 200 kPa – 400 kPa | |
| 4. Technical Specifications | Water Consumption | As low as 2 L/min | |
| 4. Technical Specifications | Noise Level | ≤ 75 dB (A) | |
| 4. Technical Specifications | Dimensions | ≤ 77 × 58 × 45 cm (vertical main unit) or 72 × 61 × 12 cm (external separator) | |
| 4. Technical Specifications | Net Weight | ≤ 100 kg | |
| 5. Configuration List | |||
| 5. Configuration List | Vacuum Pump | 1 | set / pc |
| 5. Configuration List | Separator | 1 | set / pc |
| 5. Configuration List | Vacuum Tube | 1 | set / pc |
| 5. Configuration List | Drain Pipe | 1 | set / pc |
| 5. Configuration List | Vacuum Tube | 1 | set / pc |
![]()